{"product_id":"fabisense-ht206b-true-rms-digital-clamp-meter-6000-counts-auto-ranging-ac-current-tester-with-ncv-low-z-lpf-temperature","title":"FABISENSE HT206B True RMS Digital Clamp Meter 6000 Counts Auto-Ranging AC Current Tester with NCV, Low-Z, LPF \u0026 Temperature","description":"\u003cp data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eFABISENSE HT206B Advanced AC Clamp Meter with LPF \u0026amp; Low-Z\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"19\"\u003eTake your electrical diagnostics further with the FABISENSE HT206B. Boasting an upgraded 6000-count resolution, this advanced AC clamp meter introduces high-end industrial filtering features like LPF (Low Pass Filter) and Low-Z (Low Impedance), making it ideal for HVAC technicians, industrial maintenance, and complex electrical environments.\u003c\/p\u003e\n\u003cp data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"21\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,0,0\"\u003e\u003cb data-path-to-node=\"21,0,0\" data-index-in-node=\"0\"\u003e6000 Counts \u0026amp; True RMS:\u003c\/b\u003e Delivers higher digital resolution and top-tier accuracy for precise troubleshooting on commercial electrical systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,1,0\"\u003e\u003cb data-path-to-node=\"21,1,0\" data-index-in-node=\"0\"\u003eLPF (Low Pass Filter):\u003c\/b\u003e Accurately measures voltage and current signals on variable frequency drives (VFDs) and motors by filtering out high-frequency noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,2,0\"\u003e\u003cb data-path-to-node=\"21,2,0\" data-index-in-node=\"0\"\u003eLow-Z Ghost Voltage Elimination:\u003c\/b\u003e Features a low-impedance mode that eliminates false readings caused by \"ghost voltages\" in parallel lines, ensuring absolute accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,3,0\"\u003e\u003cb data-path-to-node=\"21,3,0\" data-index-in-node=\"0\"\u003eNon-Contact Voltage (NCV) Sensor:\u003c\/b\u003e Safely scans for the presence of AC voltage without any wire contact, providing instant visual backlight shifts and audible alerts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,4,0\"\u003e\u003cb data-path-to-node=\"21,4,0\" data-index-in-node=\"0\"\u003eHVAC Temperature Tracking:\u003c\/b\u003e Includes a K-type temperature probe to record environment or contact temperatures ranging from -40°C to 1000°C (-40°F to 1832°F).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"22\"\u003e\u003cb data-path-to-node=\"22\" data-index-in-node=\"0\"\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"23\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,0,0\"\u003e\u003cb data-path-to-node=\"23,0,0\" data-index-in-node=\"0\"\u003eDisplay Counts:\u003c\/b\u003e 6000 Counts (True RMS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,1,0\"\u003e\u003cb data-path-to-node=\"23,1,0\" data-index-in-node=\"0\"\u003eAC Current Range:\u003c\/b\u003e 6A \/ 60A \/ 600A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,2,0\"\u003e\u003cb data-path-to-node=\"23,2,0\" data-index-in-node=\"0\"\u003eSpecial Filters:\u003c\/b\u003e LPF (Low Pass Filter) \u0026amp; Low-Z Mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,3,0\"\u003e\u003cb data-path-to-node=\"23,3,0\" data-index-in-node=\"0\"\u003eTemperature Spectrum:\u003c\/b\u003e -40°C~1000°C (-40°F~1832°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,4,0\"\u003e\u003cb data-path-to-node=\"23,4,0\" data-index-in-node=\"0\"\u003eFrequency \/ Duty Cycle:\u003c\/b\u003e 10Hz to 10MHz \/ 1% to 99%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,5,0\"\u003e\u003cb data-path-to-node=\"23,5,0\" data-index-in-node=\"0\"\u003eDC Voltage \/ AC Voltage:\u003c\/b\u003e Up to 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"23,6,0\"\u003e\u003cb data-path-to-node=\"23,6,0\" data-index-in-node=\"0\"\u003eWeight \/ Dimensions:\u003c\/b\u003e Approx. 188g \/ 193x73x34mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Shenzhen Fabisense Technology Co., Ltd.","offers":[{"title":"Default Title","offer_id":47420433367202,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0695\/9959\/2610\/files\/206b.jpg?v=1783652077","url":"https:\/\/www.fabisense.com\/zh\/products\/fabisense-ht206b-true-rms-digital-clamp-meter-6000-counts-auto-ranging-ac-current-tester-with-ncv-low-z-lpf-temperature","provider":"Shenzhen Fabisense Technology Co., Ltd.","version":"1.0","type":"link"}